Skip to content
Seattle, Washington
360.684.2491
206.931.4683
Shopping Cart
Courses
Course List
Fire Fighter 1&2 Courses
FEMA Courses
Courses Eligible For IFSAC/Pro Board Certification – Washington
Course Offerings for IFSAC Certification – Arizona
NFPA Fire Courses for Oregon Certification
Hazwoper Courses
NFPA 1006 Courses
Firefighter 1 & 2 Refresher for IFSAC/Pro Board Certification
Hazmat Awareness/Operations Refresher for IFSAC/Pro Board Certification
Course Calendar
About Us
About Us
Our Team
FAQs
Contact Us
Courses
Course List
Fire Fighter 1&2 Courses
FEMA Courses
Courses Eligible For IFSAC/Pro Board Certification – Washington
Course Offerings for IFSAC Certification – Arizona
NFPA Fire Courses for Oregon Certification
Hazwoper Courses
NFPA 1006 Courses
Firefighter 1 & 2 Refresher for IFSAC/Pro Board Certification
Hazmat Awareness/Operations Refresher for IFSAC/Pro Board Certification
Course Calendar
About Us
About Us
Our Team
FAQs
Contact Us
HAZWOPER Refresher Login
HAZWOPER Refresher Login
Courses
Course List
Fire Fighter 1&2 Courses
FEMA Courses
Courses Eligible For IFSAC/Pro Board Certification – Washington
Course Offerings for IFSAC Certification – Arizona
NFPA Fire Courses for Oregon Certification
Hazwoper Courses
Firefighter 1 & 2 Refresher for IFSAC/Pro Board Certification
Hazmat Awareness/Operations Refresher for IFSAC/Pro Board Certification
Course Calendar
About Us
About Us
Our Team
FAQs
Contact Us
HAZWOPER Refresher Login
Dashboard
Courses
Course List
Fire Fighter 1&2 Courses
FEMA Courses
Courses Eligible For IFSAC/Pro Board Certification – Washington
Course Offerings for IFSAC Certification – Arizona
NFPA Fire Courses for Oregon Certification
Hazwoper Courses
Firefighter 1 & 2 Refresher for IFSAC/Pro Board Certification
Hazmat Awareness/Operations Refresher for IFSAC/Pro Board Certification
Course Calendar
About Us
About Us
Our Team
FAQs
Contact Us
HAZWOPER Refresher Login
Dashboard
Fire Inspector
Practice Exam
1.
Which of the following statements about oxidizers is MOST accurate?
Oxidizers are combustible and highly volatile.
Oxidizers are neutral and do not affect combustion.
Oxidizers are combustible and also support or enhance combustion.
Oxidizers are not combustible but they will support or enhance combustion.
2.
A standard is:
usually based on a code.
a developed set of principles, protocols, or procedures.
a collection of rules and regulations enacted by a legislative body.
a legal document that governs activities at various levels of government.
3.
Why is it important for fire inspectors to maintain access and inspections of construction and demolition sites?
The conditions at these sites change frequently.
The permitting process requires constant access and inspections.
Building contractors cannot maintain business licenses without constant inspections.
Inspectors are not expected to maintain access and inspections at construction and demolition sites.
4.
What is the purpose of fire department connections as part of automatic sprinkler systems?
Protect firefighters in the structure
Allow for use of any secondary water supply
Boost the pressure of the primary water supply
Serve as a backup protection if sprinkler system fails
5.
When inspecting areas that involve noisy operations, it may be necessary to:
take notes.
use nonverbal cues.
wear hearing protection.
reschedule the inspection.
6.
Which problem is the MOST important when it comes to elevated tanks?
Open valves
Tanks with low levels
Expensive and intensive maintenance
Limitation of pressure available from the tanks
7.
A material that is used in building construction in a nonload-carrying capacity is:
steel.
wood.
concrete.
gypsum board.
8.
What type of dead-end turnaround allows a vehicle to back into a space and turn around?
"T"
Cul-de-sac
Alley dock
Hammerhead
9.
Which type of gypsum board contains vermiculite that expands as it is exposed to heat and allows the gypsum to maintain its integrity?
Type A gypsum board
Type C gypsum board
Type F gypsum board
Type X gypsum board
10.
Which of the following refers to energy released per unit of time as a fuel burns?
Heat release rate
Heat of reactivity
Heat of combustion
Realized heat energy
11.
Which of the following is the main function of a stationary fire pump?
Monitor water flow
Ensure there is an excess of supply of water
Decrease the pressure of the water that flows through it
Increase the pressure of the water that flows through it
12.
What should an inspector do to assist an owner/occupant in finding a solution to remedy a violation?
Nothing
Design a solution
Provide a copy of the code
Refer to the appropriate professional
13.
All components of emergency voice/alarm systems should be tested at least:
weekly.
monthly.
semiannually.
annually.
14.
Fire protection engineers have established _____ as the minimum required residual pressure when computing the available water for area flow-test results.
10 psi (70 kPa)
20 psi (140 kPa)
40 psi (280 kPa)
80 psi (560 kPa)
15.
Who is responsible for the inspection, testing, and maintenance of private water supply systems?
Local government
State government
Private contractor
Facility owners/occupants
16.
Which construction material used for structural members provides a large amount of fuel for combustion?
Wood
Steel
Masonry
Gypsum board
17.
Why do educational occupancies present significant challenges for inspectors?
Risk of fire is very high
Architectural design of the building
Facilities are used for a wide variety of activities
Cannot perform inspections during school hours
18.
Which component can consist of batteries with chargers, engine-driven generators with a storage battery, or multiple engine-driven generators?
Initiating device
Notification appliance
Primary power supply
Secondary power supply
19.
Kitchen grease exhaust ducts require _____ fire-resistive separation.
no
1-hour
2-hour
30-minute
20.
Under the UN system, which classification includes poison (toxic) and poison inhalation hazard?
Class 1
Class 4
Class 6
Class 9
21.
The maximum spacing between sprinklers in residential systems is:
6 feet (2 m).
12 feet (3.5 m).
20 feet (6 m).
30 feet (9 m).
22.
The special-agent fire extinguishing system most effective on fires in commercial cooking equipment that produces grease-laden vapors is a:
dry powder system.
clean agent system.
dry-chemical system.
wet-chemical system.
23.
What are the two methods that can be used to compute fire flow test results?
Historical comparison
Jacobi Method and basic math
Physics and differential equations
Graphical analysis and mathematical method
24.
Fire loss data reveals that in buildings equipped with automatic sprinklers, about _____ percent of all fires were controlled or extinguished by the sprinkler system.
fifty-five
sixty-two
ninety-four
ninety-nine
25.
Which type of sprinkler is designed to provide increased life safety in hotels, motels, and similar residential occupancies?
Open
Residential
Control mode specific application
Quick-response early suppression
26.
When codes require exit illumination, the illumination must be:
continuous during periods of occupancy.
continuous whether the building is occupied or unoccupied.
powered by at least two separate continuous power sources.
powered such that no single lighting unit will fail during occupancy.
27.
How do toxicity limits in model fire codes compare to the Department of Transportation (DOT) and Transport Canada (TC) regulations?
They are lower
They are higher
They are the same
Some differ; some match
28.
Which verbal skill requires recognizing that the listener may have a different point of view?
Engaging in a dual perspective
Being aware of any special needs of the receiver
Taking responsibility for personal feelings and thoughts
Showing respect for the feeling and thoughts of the other person
29.
What standard requires employers to identify hazards in the workplace and train employees how to recognize those hazards?
Military Hazard Identification Standard
UN's Hazard Communications Standard
OSHA's Hazard Communications Standard (HCS)
Sax's Dangerous Properties of Industrial Materials
30.
Which of the following helps prevent firefighters and emergency responders from dealing with unknown and potentially dangerous structural conditions?
Sender
Medium
Message
Interference
31.
Which of the following categories of inspection MOST likely involves responding to blocked exits?
Routine
Imminent hazard
Response to a complaint
Owner/occupant request
32.
Which of the following is MOST likely to be a factor in means of egress issues for occupants?
Common areas with multiple exits
Upper level outdoor decks or patios
Improperly designed or marked exits
Buildings that have remained unchanged
33.
Generally, exit doors used as a means of egress must be _____ doors.
sliding
folding
swinging
revolving
34.
Which glass is MOST likely to be used in security windows and to reduce noise transmission?
Laminated
Glass block
Fully tempered
Heat-strengthened
35.
Which type of fire detection and alarm system specialty signal indicates an off-normal condition of the complete fire protection system?
Alert signal
Alarm signal
Trouble signal
Supervisory signal
36.
Which guidebook is primarily a guide to aid emergency responders in quickly identifying the hazards of materials involved in an emergency incident?
Emergency Response Guidebook (ERG)
NIOSH Pocket Guide to Chemical Hazards (NPG)
Hazardous Materials Information Resource System (HMIRS)
Hazardous Materials Guide for First Responders from the U.S. Fire Administration
37.
The actual hose connections of a standpipe hose valve can be located no more than:
2 feet (.6 m) from floor level.
3 feet (.9 m) from floor level.
5 feet (1.5 m) from floor level.
6 feet (1.8 m) from floor level.
38.
Which type of sprinkler is installed downward from the branch line so that water flowing from the sprinkler strikes the deflector and is distributed over the protected area?
Flush
Pendent
Recessed
Concealed
39.
Who is usually responsible for detailed electrical inspections?
Fire inspectors
Fire commissioner
Electrical inspectors
Electrical contractors
40.
Which method allows for calculations to be made to protect all types of hazards, including extra hazards, with any type of piping and any type of sprinkler discharge device?
Previous usage
Pipe schedule tables
Hydraulic calculations
Correlation of hazards
41.
Why are wood shingles and shakes treated with fire-retardant chemicals difficult for inspectors to identify?
Contractors fail to retain documentation.
Fire-retardant chemicals do not have odor.
Paper identification labels are not visible after installation.
Exposure to weather elements destroys identification markers.
42.
What organization has codes or standards that apply to hazardous materials and includes Boiler and Pressure Vessel Code, Section VIII, Division 1 and 2?
UL
ICC
ASME
NFPA®
43.
What is another name for an intermediate bulk container (IBC)?
Tote
Drum
Safety can
Safety cylinder
44.
Two main hazards associated with recycling plants include:
high fuel loads and improper storage.
bulk storage and hazardous processes.
bulk storage and limited staff presence.
hazardous processes and high fuel loads.
45.
Inspectors following the same sequence for similar types of occupancies increases the:
efficiency of the paperwork.
preparedness of owner/occupants.
consistency of the inspection process.
number of inspections that can be conducted.
46.
When it comes to product containment, what is one of the greater problems inspectors will find?
The improper labeling of products
The lack of security of the products
The training requirements for personnel
The design and construction of storage tanks
47.
A _____ can be installed in large, vertical overhead doors to act as a means of egress.
sliding door
folding door
swinging door
revolving door
48.
Which of the following locking hardware should be able to be operated by occupants setting the door in motion by applying a force of no more than 30 pounds (15 N)?
Bolt locks
Panic hardware
Access-controlled egress
Electromagnetically locked
49.
Unless they are disposable, compressed gas containers are subject to periodic testing and:
cleaning.
replacement.
maintenance.
examination.
Loading...